Mass timber has moved from novelty to a mainstream option for mid-rise and, increasingly, tall buildings, helped by code changes that recognise its fire performance. Designing with CLT and glulam is not simply substituting wood for concrete. This briefing covers the code path, fire design, structural behaviour, connections and the hybrid systems that make tall wood practical.
The products
Cross-laminated timber consists of layers of lumber glued at right angles, producing large, stiff panels for floors, walls and roofs. Glued-laminated timber, or glulam, bonds laminations with grain parallel to form beams and columns. Other products include nail-laminated and dowel-laminated timber and laminated veneer lumber. Product standards, such as ANSI/APA PRG 320 for CLT, define manufacturing and performance requirements.
Prefabrication is central to mass timber: panels are cut to precise dimensions with openings and connections machined in the factory, enabling fast, quiet site assembly.
Supply has expanded with new North American CLT and glulam plants, but capacity, product sizes and lead times vary by manufacturer. Engaging suppliers early, and designing around standard panel sizes and grades, improves cost and schedule.
The code path
The 2021 International Building Code introduced Types IV-A, IV-B and IV-C construction, allowing mass timber buildings up to 18, 12 and 9 stories respectively, with different requirements for noncombustible protection of timber surfaces. Adoption varies by state and jurisdiction, and some local codes have adopted these provisions earlier or with amendments. Early engagement with building officials and fire marshals is important, particularly on first projects in a jurisdiction.
Fire design
Large timber members char at a predictable rate when exposed to fire, forming an insulating layer that protects the inner core. Fire resistance can be demonstrated by calculation, using char rates to determine remaining section capacity, or by testing. Taller construction types require encapsulation with gypsum board or other noncombustible materials to limit the timber's contribution to fire.
Connections need particular attention, since steel connectors can conduct heat into members. Concealing connections within the timber or protecting them is common.
Structural behaviour
Timber is light, which reduces foundation loads and seismic mass, but floors may be governed by vibration and acoustic performance rather than strength. Floor assemblies often include concrete toppings or acoustic layers. Long-term creep, shrinkage and differential movement between timber and concrete or steel elements must be considered, especially in taller buildings where cumulative column shortening matters.
Lateral systems commonly use concrete or steel cores, though CLT shear walls and timber braced frames are used in some buildings.
Seismic design of mass timber buildings often relies on the core or dedicated lateral systems, with timber diaphragms transferring forces. Diaphragm and collector design, using CLT panels with screwed or splined connections, needs careful detailing.
Connections
Connections determine much of mass timber's structural performance, ductility and constructability. Self-tapping screws, dowels, bearing plates and proprietary connectors are common. Designs must address splitting, edge distances, moisture and tolerances. Coordination between the engineer, manufacturer and installer is critical, since connections are often machined in the factory.
Many projects use standardised connection details across the building to simplify fabrication and installation. Testing data for proprietary connectors, and their fire performance, should be confirmed for the intended application.
Moisture and construction
Timber exposed to rain during construction can swell, stain or grow mould, and trapped moisture can cause long-term problems. Moisture management plans include temporary protection, rapid enclosure, moisture monitoring and allowing drying before finishes. Fast erection helps reduce exposure.
Sustainability is a major driver for mass timber, since wood stores carbon and can have lower embodied emissions than concrete and steel. Lifecycle assessments should consider forest sourcing, transport and end-of-life assumptions to make credible claims.
Key takeaways
- CLT and glulam are prefabricated, enabling fast, precise assembly.
- Recent IBC editions allow mass timber up to 18 stories.
- Fire resistance relies on predictable charring and encapsulation.
- Vibration, acoustics and movement often govern design.
- Connections and moisture management are critical.
Frequently asked questions
- Is mass timber safe in fire?
- Large timber members char predictably and retain structural capacity; codes specify fire resistance and encapsulation requirements.
- What is CLT?
- Cross-laminated timber, panels made of layers of lumber glued at right angles.
- Why use concrete cores with mass timber?
- Cores provide lateral stiffness and fire-rated egress, complementing timber floors and columns.
- Does mass timber reduce embodied carbon?
- It often can compared with concrete and steel, depending on sourcing, transport and assumptions about carbon storage and end of life. A project-specific lifecycle assessment gives the clearest answer.
Need an engineer for this kind of work?
Describe your project and we will match you with licensed firms that specialise in construction engineering.
EngineerMint Insights are editorial briefings, not engineering advice. Verify with a licensed engineer before applying to a specific project.