Tall buildings concentrate many of structural engineering's hardest problems: wind-induced motion, seismic demands, foundations in difficult ground, and the economics of floor space versus structure. Mass timber is now pushing into the high-rise category as well. This briefing covers the current state of practice in tall-building structural design and where it is heading.
Wind governs as buildings get taller
As height increases, wind loads and wind-induced motion often govern structural design more than gravity loads. Occupant comfort, measured by accelerations at upper floors, can control stiffness requirements even when strength is adequate. Vortex shedding, where wind creates alternating forces that can cause across-wind oscillation, is a particular concern for slender towers.
Wind tunnel testing remains standard for tall and unusual buildings, providing pressures and overall loads more accurately than code methods. Computational fluid dynamics is increasingly used in early design but generally complements rather than replaces testing.
Shaping and damping
Architectural shaping, such as tapering, setbacks, corner modifications and openings, can significantly reduce wind response by disrupting vortex shedding. Close collaboration between architects and structural engineers early in design can produce more efficient structures.
Supplemental damping systems, including tuned mass dampers and tuned liquid dampers, reduce motion at the top of slender towers. They add cost and space but can be more economical than adding stiffness.
Structural systems
Common systems include reinforced concrete core walls, outrigger and belt truss systems that engage perimeter columns, tube systems and diagrids. Outriggers connect the core to perimeter columns, increasing stiffness efficiently. Concrete has become prevalent for very tall buildings because of its stiffness, damping and fire resistance, often in composite combination with steel.
System choice is shaped by floor plate efficiency as much as structural performance. Large cores and closely spaced columns reduce rentable area, so engineers and architects balance stiffness against usable space. Outriggers are often placed at mechanical floors where their depth does not interfere with occupied space.
Construction sequence affects design. Differential shortening between concrete cores and steel or composite perimeter columns, caused by creep and shrinkage, must be predicted and compensated during construction to keep floors level.
Seismic design and performance-based approaches
In seismic regions, tall buildings are often designed using performance-based approaches, such as those described in the PEER Tall Buildings Initiative guidelines and the Los Angeles Tall Buildings Structural Design Council procedures. These use nonlinear analysis to demonstrate acceptable performance under specified earthquake levels, often with peer review. This allows systems that may not fit prescriptive code limits, such as core-only lateral systems in tall buildings.
Performance-based design typically involves selecting and scaling ground motion records for the site, building detailed nonlinear models and checking deformation and force demands against acceptance criteria. Independent peer review panels provide additional assurance and are often required by jurisdictions using this approach.
Foundations
Tall buildings impose large concentrated loads, requiring deep foundations such as piles, piled rafts or caissons. Soil-structure interaction, differential settlement and construction sequence effects must be analysed. In dense urban sites, adjacent structures, existing utilities and excavation support add complexity.
Load testing of piles, monitoring of settlement during construction and careful excavation support design are standard. Where adjacent buildings are sensitive, instrumentation and protective measures such as underpinning may be required.
The tall timber revolution
Recent International Building Code editions introduced construction types IV-A, IV-B and IV-C, allowing mass timber buildings up to 18 stories, depending on type and fire protection. Tall timber buildings typically use cross-laminated timber floors and glulam columns and beams, often with concrete cores. Design challenges include connection behaviour, vibration, shrinkage, fire protection and moisture during construction. Hybrid timber-concrete and timber-steel systems are common.
Key takeaways
- Wind and occupant comfort often govern tall building design.
- Shaping and supplemental damping can reduce wind response efficiently.
- Performance-based seismic design enables tall buildings in seismic regions.
- Foundations must address large loads and soil-structure interaction.
- Building codes now allow mass timber buildings up to 18 stories.
Frequently asked questions
- Why do tall buildings need wind tunnel testing?
- Wind effects on tall, slender buildings are complex, and testing provides more accurate loads and motion predictions than code methods.
- What is a tuned mass damper?
- A large mass mounted near the top of a building, tuned to counteract the building's motion and reduce accelerations.
- How tall can mass timber buildings be?
- Recent IBC editions allow up to 18 stories under Type IV-A construction, subject to fire protection requirements.
- What is an outrigger system?
- A structural system of stiff trusses or walls connecting a building's core to its perimeter columns, increasing lateral stiffness and reducing wind and seismic drift.
Need an engineer for this kind of work?
Describe your project and we will match you with licensed firms that specialise in construction engineering.
EngineerMint Insights are editorial briefings, not engineering advice. Verify with a licensed engineer before applying to a specific project.